PROSEDUR PEMERIKSAAN CT SCAN KEPALA DENGAN KLINIS STROKE HEMORRHAGIC DI RS PKU MUHAMADIYAH YOGYAKARTA
DOI:
https://doi.org/10.51878/cendekia.v5i4.7153Keywords:
CT Scan, kepala, stroke hemorrhagic, slice thicknessAbstract
This study was motivated by variations in head CT scan protocols for hemorrhagic stroke cases. While general practice uses a 5-8 mm slice thickness, PKU Muhammadiyah Hospital Yogyakarta employs a 2 mm slice thickness, accompanied by hemorrhage volume calculations. This discrepancy between general practice and the specific protocol necessitates an in-depth analysis. Therefore, this study focuses on describing the examination procedure, analyzing the rationale for using a 2 mm slice thickness, and understanding the role of hemorrhage volume calculations. This study employed a qualitative method with a case study approach involving three radiographers, one radiologist, and one patient. Data collection was conducted through observation, interviews, and documentation. The results showed that the procedures implemented were in accordance with theoretical standards. Key findings revealed that the use of a 2 mm slice thickness aims to produce higher image detail, allowing for clearer visibility of intracerebral hemorrhage. Furthermore, automatic hemorrhage volume calculations play a crucial role in determining neurosurgical procedures. It was concluded that this specific protocol is effective for diagnosis and treatment planning, but additional fixation and radiation protection of the ocular lens are recommended to optimize patient safety.
ABSTRAK
Penelitian ini dilatarbelakangi oleh adanya variasi protokol dalam pemeriksaan CT Scan kepala untuk kasus strok hemoragik, di mana praktik umum menggunakan slice thickness 5-8 mm, sedangkan di RS PKU Muhammadiyah Yogyakarta diterapkan slice thickness 2 mm disertai perhitungan volume perdarahan. Kesenjangan antara praktik umum dengan protokol spesifik ini mendorong perlunya analisis mendalam. Oleh karena itu, penelitian ini berfokus untuk mendeskripsikan prosedur pemeriksaan, menganalisis alasan penggunaan slice thickness 2 mm, dan mengetahui peran perhitungan volume perdarahan. Penelitian ini menggunakan metode kualitatif dengan pendekatan studi kasus yang melibatkan tiga radiografer, satu dokter spesialis radiologi, dan satu pasien. Pengumpulan data dilakukan melalui observasi, wawancara, dan dokumentasi. Hasil penelitian menunjukkan bahwa prosedur yang diterapkan telah sesuai dengan standar teori. Temuan utama mengungkap bahwa penggunaan slice thickness 2 mm bertujuan untuk menghasilkan detail citra yang lebih tinggi sehingga perdarahan intraserebral dapat terlihat lebih jelas. Selain itu, perhitungan volume perdarahan secara otomatis berperan krusial dalam menentukan tindakan bedah saraf. Disimpulkan bahwa protokol spesifik ini efektif untuk diagnosis dan perencanaan terapi, namun direkomendasikan penambahan fiksasi dan proteksi radiasi pada lensa mata untuk mengoptimalkan keamanan pasien.
Downloads
References
Alnutayfi, H., et al. (2019). Comparison between the CT & MRI for meningioma in the brain in King Khalid University Hospital Riyadh K.S.A. International Journal of Advanced Research, 7(1), 1232–1238. https://doi.org/10.21474/ijar01/8445
Dewilza, N., et al. (2023). Gambaran noise pada pemeriksaan CT-Scan brain menggunakan protokol fast stroke. Jurnal Kesehatan Tambusai, 4(4), 6547–6554. https://doi.org/10.31004/jkt.v4i4.21295
Familah, A., et al. (2024). Characteristics of ischemic stroke and hemorrhagic stroke patients. Fakumi Medical Journal: Journal of Medical Students, 4(6), 456–463. https://doi.org/10.33096/fmj.v4i6.468
Fitriana, L., & Utami, H. S. (2021). Perbedaan nilai image noise dan dosis radiasi dengan menggunakan automatic exposure control (AEC) pada pemeriksaan CT scan. Jurnal Kesehatan, 12(2), 131–136. https://doi.org/10.38165/jk.v12i2.259
Fitriyani, & Irawan, W. K. (2023). Stroke hemoragik pada pasien dengan riwayat stroke iskemik. Medula, 13(7), 1248–1252. https://doi.org/10.53089/medula.v13i7.893
Handi, P. S. I. N., & Anjani, M. (2024). Teknik pemeriksaan CT scan kepala non kontras dengan kasus CVA di Instalasi Radiologi Rumah Sakit Baptis Kota Kediri. Strada Journal of Radiography, 5(2), 5–9. https://doi.org/10.30994/sjr.v4i2.46
Istiqomah, A. N., et al. (2022). A study of eye lens radiation dose reduction during head CT Scan examination. Journal of Medical Imaging and Radiation Sciences, 53(4), S25. https://doi.org/10.1016/j.jmir.2022.10.084
Kiswoyo, A. S., et al. (2023). Penghitungan volumetrik perdarahan dengan metode volume automatik (software volume evaluation) dan metode manual (Broderick) pada MSCT kepala (study eksperimen pada pasien perdarahan intraserebral di RS. Haji Surabaya). Jurnal Imejing Diagnostik (JImeD), 3(2), 231–235. https://doi.org/10.31983/jimed.v3i2.3190
Lampignano, J. P., & Kendrick, L. E. (2018). Textbook of radiographic positioning and related anatomy (9th ed.). Mosby Elsevier.
Masrochah, S., et al. (2021). Metode pengukuran volume perdarahan pemeriksaan MSCT kepala pada kasus intraserebral hemmorhage. Jurnal Imejing Diagnostik (JImeD), 7(1), 1–7. https://doi.org/10.31983/jimed.v7i1.6612
Parinding, N. T. A., et al. (2015). Gambaran hasil pemeriksaan CT scan kepala pada penderita stroke hemoragik di Bagian Radiologi FK. Unsrat/SMF Radiologi BLU RSUP Prof. Dr. R. D. Kandou Manado. E-CliniC, 3(1), 1–5. https://doi.org/10.35790/ecl.3.1.2015.6746
Rizky, I., et al. (2024). Prosedur pemeriksaan CT scan kepala dengan klinis stroke hemorrhagic di RS Bhayangkara Makassar. Journal of Educational Innovation and Public Health, 2(1), 101–106. https://doi.org/10.55606/innovation.v2i1.2096
Saputri, R., et al. (2023). Literatur review teknik pemeriksaan CT-Scan kepala klinis cephalgia. JRI (Jurnal Radiografer Indonesia), 6(2), 93–97. https://doi.org/10.55451/jri.v6i2.222
Seeram, E. (2022). Computed tomography-e-book. Elsevier Health Sciences.
Tarkiainen, J., et al. (2023). Radiation dose of the eye lens in CT examinations of the brain in clinical practice—The effect of radiographer training to optimise gantry tilt and scan length. Radiation Protection Dosimetry, 199(5), 391–398. https://doi.org/10.1093/rpd/ncad002
Utami, A. P., et al. (2018). Prosedur pemeriksaan CT scan kepala pada kasus cerebrovascular accident (CVA) bleeding di Instalasi Radiologi Rumah Sakit TK.II 04.05.01 Dr. Soedjono Magelang. Jurnal Ilmu Dan Teknologi Kesehatan, 4(2), 16–19. https://doi.org/10.33666/JITK.V4I2.88